Measuring Young’s modulus of single trabeculae in cancellous bone using a two-point bending test

Clausing RJ 1 , Stiller A 1 , Kuhn F 1 , Fonseca Ulloa CA 1 , Fölsch C 2 , Kampschulte M 3 , Krombach GA 3 , Rickert M 2 , Jahnke A 4

Clin Biomech (Bristol, Avon). 2023 Feb:102:105875.doi: 10.1016/j.clinbiomech.2023.105875 . Epub 2023 Jan 5.

„Measuring Young’s modulus of single trabeculae in cancellous bone using a two-point bending test“ weiterlesen

Retrospective clinical and X-ray-based outcome analysis of a short-stem hip arthroplasty taking into account the operative learning curve over 7 years in the 3-year control course

Jahnke A 1 , Köther-Herrmann J 1 , Fonseca Ulloa CA 1 , Harz T 1 , Rickert M 1,2 , Ishaque BA 3 4.

Arch Orthop Trauma Surg. 2023 Nov;143(11):6589-6597.doi: 10.1007/s00402-023-04977-w . Epub 2023 Jul 7.

„Retrospective clinical and X-ray-based outcome analysis of a short-stem hip arthroplasty taking into account the operative learning curve over 7 years in the 3-year control course“ weiterlesen

Development and validation of an algorithm to determine the minimal factors needed for non-invasive measurement of the in vivo primary stability of cementless hip implants

Fonseca Ulloa CA 1 , Seeger A 2 , Hagedorn FS 3 , Harz T 2 , Fölsch C 4 , Ishaque BA 4 , Rickert M 4 , Jahnke A 2

Med Eng Phys. 2023 Jan:111:103932.doi: 10.1016/j.medengphy.2022.103932. Epub 2022 Dec 1.

„Development and validation of an algorithm to determine the minimal factors needed for non-invasive measurement of the in vivo primary stability of cementless hip implants“ weiterlesen

Acoustical determination of primary stability of femoral short stem during uncemented hip implantation

Fonseca Ulloa CA 1 , Schreynemackers S 2 , Harz T 3 , Lang FW 3 , Fölsch C 4 , Rickert M 4, Jahnke A 3 , Ishaque BA 4

Clin Biomech (Bristol, Avon). 2023 Oct:109:106079.doi:10.1016/j.clinbiomech.2023.106079 Acoustical determination of primary stability of femoral short stem during uncemented hip implantation. Epub 2023 Aug 22.

„Acoustical determination of primary stability of femoral short stem during uncemented hip implantation“ weiterlesen

Micromotion measurement at the interfaces of cemented tibial endoprosthetic replacements: A new standardized in vitro model using open-cell rigid foam

Fölsch C 1 , Fonseca Ulloa CA 2 , Harz T 2 , Schirmer J 2 , Glameanu C 3 , Scherberich J 4 , Krombach G 4 , Rickert M 3 , Martin JR 5 , Kühn KD 6 , Jahnke A 2

Med Eng Phys. 2023 Sep:119:104027. doi: 10.1016/j.medengphy.2023.104027. Epub 2023 Jul 20.

„Micromotion measurement at the interfaces of cemented tibial endoprosthetic replacements: A new standardized in vitro model using open-cell rigid foam“ weiterlesen

Determination of E-modulus of cancellous bone derived from human humeri and validation of plotted single trabeculae: Development of a standardized humerus bone model

Kuhn F 1 , Clausing RJ 1 , Stiller A 1 , Fonseca Ulloa CA 1 , Foelsch C 2 , Rickert M 2 , Jahnke A 1

J Orthop. 2022 Jul 11:33:48-54. doi: 10.1016/j.jor.2022.07.003. eCollection 2022 Sep-Oct.

„Determination of E-modulus of cancellous bone derived from human humeri and validation of plotted single trabeculae: Development of a standardized humerus bone model“ weiterlesen